MYT serise Manual type 2D Video Measuring Machine

Short Description:

HD-322MYT manual video measurement instrument.Image software: it can measure points, lines, circles, arcs, angles, distances, ellipses, rectangles, continuous curves, tilt corrections, plane corrections, and origin setting. The measurement results display the tolerance value, roundness, straightness, position and perpendicularity. 


  • Effective Space: 200mm
  • Working Distance: 90mm
  • X/Y linear measurement accuracy (μm): ≤3+L/200
  • Computer: Customized computer host
  • Display: 21 inches
  • Product Detail

    Product Tags

    Main Technical Parameters and Characteristics of the Machine

    Model

    HD-2010M

    HD-3020M

    HD-4030M

    HD-5040M

    X/Y/Z measurement stroke

    200×100200mm

    300×200200mm

    400×300200mm

    500×400200mm

    Z axis stroke

    Effective space: 200mm, working distance: 90mm

    XYZ axis base

    Grade 00 green marble

    Machine base

    Grade 00 green marble

    Size of glass countertop 

    250×150mm

    350×250mm

    450×350mm

    550×450mm

    Size of marble countertop

    360mm×260mm

    460mm×360mm

    560mm×460mm

    660mm×560mm

    Bearing capacity of glass countertop

    25kg

    Transmission type

    High precision cross drive guide and polished rod

    Optical scale

    High precision optical scale resolution: 0.001mm

    X/Y linear measurement accuracy (μm)

    ≤3+L/200

    Repetition accuracy (μm)

    ≤3

    Camera

    1/3″ HD color industrial camera

    Lens

    Fixed zoom lens, optical magnification: 0.7X-4.5X,

    image magnification: 20X-128X

    Software function and  Image system

    Image software: it can measure points, lines, circles, arcs, angles, distances, ellipses, rectangles, continuous curves, tilt corrections, plane corrections, and origin setting. The measurement results display the tolerance value, roundness, straightness, position and perpendicularity. The degree of parallelism can be directly exported and imported into Dxf, Word, Excel, and Spc files for editing which is suitable for batch testing for customer report programming. At the same time, part of and the entire product can be photographed and scanned, and the size and image of the entire product can be recorded and archived, then the dimensional error marked on the picture is clear at a glance.

    Image card: SDK2000 chip image transmission system, with clear image and stable transmission.

    Illumination system

    Continuously adjustable LED light (Surface illumination +contour illumination), with lower heating value and long service life

    Overall dimensionL*W*H

    100600×1450mm

    110700×1650mm

    135900×1650mm

    1601100×1650mm

    Weightkg

    100kg

    150kg

    200kg

    250kg

    Power supply

    AC220V/50HZ AC110V/60HZ

    Computer

    Customized computer host

    Display

    21 inches

    Warranty

    1 year warranty for the whole machine

    Switching power supply

    Mingwei MW 12V

    Working Environment of Instrument

    manual vmm322

    Temperature and humidity
    Temperature: 20-25℃, optimal temperature: 22℃; relative humidity: 50%-60%, optimal relative humidity: 55%; Maximum temperature change rate in the machine room: 10℃/h; It is recommended to use a humidifier in dry area, and use a dehumidifier in humid area.

    Heat calculation in the workshop
    ·Keep the machine system in the workshop operating in the optimum temperature and humidity, and the total indoor heat dissipation must be calculated, including the total heat dissipation of indoor equipment and instruments (lights and general lighting can be ignored)
    ·Heat dissipation of human body: 600BTY/h/person
    ·Heat dissipation of workshop: 5/m2
    ·Instrument placement space (L*W*H): 2M ╳ 2M ╳ 1.5M

    Dust content of air
    The machine room shall be kept clean, and the impurities greater than 0.5MLXPOV in the air shall not exceed 45000 per cubic foot. If there is too much dust in the air, it is easy to cause resource read and write errors and damage to the disk or read-write heads in the disk drive.

    Vibration degree of machine room
    The vibration degree of machine room shall not exceed 0.5T. Machines that vibrate in the machine room shall not be placed together, because the vibration will loosen the mechanical parts, joints and contact parts of the host panel, resulting in abnormal operation of the machine.

    Power Supply

    AC220V/50HZ

    AC110V/60HZ